Warm water floors provide an opulent and effective means of heating your house. Warm water is circulated via a system of pipes underneath your flooring to give you comfortable, steady warmth. The collector is one of the key elements in guaranteeing warm water floors operate at their best. Collectors control the flow of hot water, ensuring that the proper amount of warmth reaches every part of your floor.
Tim, a well-known brand in the heating sector, provides a large selection of excellent collectors made especially for warm water floor systems. These collectors are renowned for being long-lasting, effective, and simple to install. Tim’s collectors offer dependable performance to preserve a cozy interior atmosphere whether you are installing a new heating system or updating an old one.
Tim offers a range of models with different types of collectors to accommodate varying system sizes and heating requirements. Every type of home can find a solution, ranging from basic manual choices to sophisticated automated models. The precise engineering of each collector guarantees ideal water flow and temperature control, enhancing the overall effectiveness of your heating system.
For your warm water floor system, selecting the appropriate collector can have a big impact on comfort and energy savings. Tim’s products offer flexibility and peace of mind because they are made to work seamlessly with a variety of flooring and heating setups. For homeowners seeking to improve their heating solutions, Tim remains a reliable option, emphasizing both quality and innovation.
Tim’s line of warm water floor collectors is notable for its creative designs, robust construction, and effectiveness. Because of the way these collectors are designed, your floor heating system will operate more dependably and efficiently. Tim offers solutions that blend cutting-edge technology with simple installation and upkeep, with a range of models catered to various needs and preferences. Tim’s collectors provide a premium option that improves comfort and energy savings in any home, whether you’re installing a new system or upgrading your existing one.
- About the manufacturer
- Equipment Features
- Types of distribution devices
- KD series
- KDS
- KC
- KCS
- K.A
- KAS
- Installation features
- Possible problems during operation
- Advantages and disadvantages
- Reviews
- Useful video
- Video on the topic
- Review of the Tim manifold assembly. Installation of underfloor heating in cottages. Ufa
- Underfloor heating manifold. Thermal mixing unit. Device. What it consists of, why it is needed?
- Review of the TIM stainless steel heating and floor manifold.
About the manufacturer
TIM is a sizable company with production sites in southern China; its goods are among the best on the market. For over a decade, the engineering plumbing range has been available in the market. During this time, the company has established itself as a dependable and productive manufacturer.
The brand’s primary focus is on engineering systems used in the installation and maintenance of water supply, heating, and other systems put together with different pipeline structures.
These days, the following categories of engineering plumbing represent the company’s offering:
- Pumps and auxiliary equipment.
- Pipe products and fittings for pipelines.
- Shut-off valves for pipes, including fittings and plugs.
- Filter elements and materials for filters.
- Heating system equipment (including distribution manifolds for underfloor heating systems).
Equipment Features
There are some variations in this company’s collector systems:
- Mounted on soundproof brackets.
- Has the ability to connect from different sides.
- Has the ability to easily adjust individual heating circuits.
Types of distribution devices
Let’s think about a few possibilities.
KD series
This is a line of flow-meter equipped collectors that can be used in underfloor heating systems as well as water supply systems.
Pipeline systems that convey liquids (water, liquids containing ethylene glycol) that are not aggressive to the distribution unit’s composition use this kind of collector group. When transporting a carrier that is below freezing, the maximum amount of ethylene glycol that can be added to the solution shouldn’t be greater than 30%.
Technical details of the item:
- Product material – brass.
- Number of outgoing messages – from 3 to 12 pieces.
- Tmax of working fluid – 110 degrees Celsius.
- Tmax short-term – 120 degrees Celsius.
- Maximum pressure – 0.6 MPa.
- Test pressure – 0.6 bar.
- Incoming manifold thread – 1” internal.
- Outgoing connection diameter – 3/4“ eurocone
- Maximum pressure drop – 10 bar.
- Service life (average) – up to 6.5 years.
Characteristics of this series’ manifold units:
- Exceptional accuracy of flow regulation by circuit.
- Ability to control the pressure of each circuit.
- Insignificant pressure loss.
- Exclusion of individual circuits.
- Ability to connect servo drives.
- Ease of installation.
The official dealer’s website lists the following overall dimensions: The article’s figure represents the total number of outgoing lines. KD003, for instance, is a manifold with three outgoing.
The product’s average cost starts at 2,800 rubles and varies based on the quantity of outgoing and pressure regulators that result from it.
KDS
This group of manifolds includes air bleeders, thermostatic valves with manual adjustment mechanisms, and adjustment valves. The purpose of this set of manifolds is to distribute flow along the underfloor heating branches. A non-freezing solution with a maximum temperature of 90 degrees Celsius that contains glycol or water can be transported via the pipelines. Additionally, the manifold unit’s working pressure is 1 MPa.
Features of the manifolds of the KDS series:
- Product material – stainless steel.
- Number of outgoing – from 2 to 12 pieces.
- Tmax of the working fluid – 70 degrees Celsius.
- Tmax short-term – 90 degrees Celsius.
- Minimum operating temperature of the system – 5 degrees Celsius.
- Maximum pressure – 0.6 MPa.
- Test pressure – 0.6 bar.
- Manifold thread on the incoming – 1” internal.
- Outgoing connection diameter – 3/4" Eurocone
- Maximum pressure drop – 10 bar.
- Service life (average) – up to 6.5 years.
Shares characteristics with the KD series.
The following overall dimensions can be found on the dealer’s official website: The number of outputs is indicated by the number in the article number. KDS5002, for instance, is a manifold with two outgoing.
The product ranges in price from 2,300 rubles on average, based on the manifold’s design features (number of outgoing, number of mechanical regulators).
KC
Additionally, collectors in this series are outfitted with brass Mayevsky taps, which can withstand a maximum peak load of 110 degrees Celsius. This manifold has a minimum operating temperature of -20 degrees Celsius. They are the same as the KD series in every other way. The number of outputs is the numerical expression found in the article number. Take the collector block with four outgoing lines, KC004, as an example.
Products starting at 4400 rubles in price range.
KCS
The collector group is outfitted with this:
- flow meters, mechanical manual regulators with air vents;
- drain valves and thermal valves.
The distributor splits the flow of working fluid (solutions containing glycol or water) at a temperature not to exceed 70 degrees Celsius. The system can withstand operating pressures of up to 0.6 MPa.
The characteristics of the manufacturer Tim’s manifold groups dictate the features of the series.
The following product sizes in this series are listed on the website of the company’s Russian dealer: The article’s numbers represent the number of lines that come out of the collector. KCS5011, for instance, is a collector block with eleven descending lines.
K.A
This group of products has the highest configuration:
- equipped with shut-off valves;
- Mayevsky cranes;
- flow meters.
Because the collectors in this series have brass bodies, they can tolerate peak loads of up to 110 degrees Celsius.
Solutions that contain glycol and water represent the liquid series that can be used as a coolant.
Every coolant supply circuit in the collectors of this series has a flow meter installed. The following are the collectors’ measurements as listed on the dealer’s website: These collectors are unique in that they have automated drain and air bleed valves built right in.
The number of outgoing is one of the many things that the article number indicates. One collector unit with eight output lines is the KA008.
KAS
Exactly the same as the KA series, with the exception of the material used in construction, the collectors’ shape, and the operating temperature. Tim, the manufacturer, states that the maximum temperature for their stainless steel collectors is ninety degrees Celsius. The dealer’s website displays the distributors’ dimensions in the following format: Where the number of collector lines can be ascertained by the article number: A collector with five outgoings is KAS5005.
Installation features
Let’s examine a few guidelines:
- Clean the pipeline on which the manifold group will be installed from corrosive deposits.
- Install the manifold, horizontally connecting it to the pipeline using cylindrical pipe threads.
- Connect the manifolds on which the control valves are located to the coolant supply pipeline.
- Connect the collectors on which the shut-off valves are installed to the return pipeline.
- Using brackets, mount the manifold to the wall or cabinet. The air vent must be located at the highest point, and the collector must be hung strictly vertically.
- Threaded connections are fixed using winding material, polyamide thread with silicone or Fuma tape.
- It is necessary to check that parts of the winding material do not get into the valve seats.
- The system is filled using closed air vents. At the end of the installation, you need to check the tightness of the system, this will prevent leaks.
- Hydraulic tests are carried out only after installing air vents or opening the shut-off valves in front of them.
- To put the air vent in the working position, you need to slightly unscrew the protective cap located on the top of the cover, without removing it.
- Before putting the manifold into operation, it is necessary to tighten all the compression nuts.
Possible problems during operation
Tim distribution devices have common issues that they encounter and common solutions for them. Let’s look at a few:
- Air entering the system. A possible problem in multi-story buildings. To avoid this, independent manifold blocks should be placed on each floor.
- Getting winding material into the valve seats. You should carefully install and monitor the winding. Otherwise, you will have to wind and connect again.
- Different circuits warm up differently. It will be necessary to adjust the balancing valves.
Advantages and disadvantages
Among the benefits that we can list are:
- Complete set with soundproof brackets.
- Wide range of configurations.
- Work on water and a mixture of water with antifreeze.
The abundance of counterfeit products on the market is a drawback for the brand’s distribution methods.
Reviews
This is what customers have to say about the brand, which is widely used in our nation because it promotes fairly democratic pricing:
- Good price/quality ratio. Adjusts normally. You can organize the supply of communications from any side.
- Has a complete set for connection, assembles without additional winding.
- Simple operating instructions.
- Assembly of the kit is intuitive even without instructions.
- The price is very pleasant compared to other manufacturers.
Reviews are available for reading here.
Useful video
Extra details in the video:
Model | Characteristics |
Tim Basic | Durable brass construction, suitable for small areas, easy installation |
Tim Pro | Stainless steel, handles larger areas, includes flow meters for precise control |
Tim Smart | Integrated temperature sensors, remote monitoring, energy efficient |
Tim’s warm water floor collectors provide a dependable and effective answer to today’s heating requirements. Their superior construction and cutting-edge design guarantee peak performance, which makes them an invaluable complement to any underfloor heating system. With a variety of models to choose from, homeowners can find the ideal match for their unique installation needs.
Every collector is designed to be long-lasting and user-friendly, with features that make installation easier and improve functionality over time. In addition to encouraging uniform heat distribution, the well-considered design helps to maintain steady water flow, which is essential for comfort and energy efficiency.
Tim’s collectors are unique in the market because they combine creativity and pragmatism. These collectors offer a solid basis for a warm water floor system that works well, whether you are building a new building or remodeling an existing area. They are a fantastic option for guaranteeing a cozy and energy-efficient home environment because of their adaptability and strong performance.